Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes

Product Details
Customization: Available
Application: Biotechnology Industry, Chemical industry, Clinical Diagnosis, Food & Beverage Factory, Food Safety, Forensic Science, Pharmaceutical Industry
Capacity: 20000 L/hr
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
Quality Assurance
The supplier provides quality assurance
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
RoHS
to see all verified strength labels (13)
  • Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
  • Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
  • Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
  • Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
  • Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
  • Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
Find Similar Products

Basic Info.

Model NO.
MY-FS
Certification
CE, FDA, GMP, ISO
Control System
Fully Automatic
Treatment Process
Filtration, Ultrafiltration
Warranty of core components
1 Year
Tank Material
Stainless Steel 316L
Temperature Resistance
150ºC
Working Volume
2~15000L
Weighing Control Accuracy
3%
Power Supply
380V 50Hz
Sealing and Protection Levels
IP65
Temperature Control Accuracy
Temperature Range-10~150ºC ±0.2ºC
Stirring Speed Control Accuracy
Speed Range 0~450rpm ±3.0%
Pressure Control Accuracy
Pressure Range-0.01MPa~0.06MPa ±0.01MPa
Transport Package
Wooden Box
Specification
350*180*300
Trademark
Marya
Origin
China

Packaging & Delivery

Package Size
350.00cm * 180.00cm * 300.00cm
Package Gross Weight
3500.000kg

Product Description

Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes

Introduction

The formulation system is engineered to provide precise control and monitoring of the key parameters during the formulation of pharmaceutical products. The integrated temperature and pressure probes play a vital role in this regard. The temperature probes are highly accurate, capable of measuring even the slightest fluctuations in the temperature within the vessel. The pressure probes, on the other hand, monitor the internal pressure of the vessel. This is essential for processes that involve reactions under specific pressure conditions or when dealing with volatile substances.
 
Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes

Classification
 
1.General formulation system: It is used for general small        molecule chemical preparation, such as aqueous injection,      lyophilized powder injection and so on.
Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
2.Complex formulation system: It is used in the production of preparations with complex processes, such as suspensions, emulsions, liposomes, microspheres and other special preparations.
Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
 
3.Biological formulation system: It is used for the preparation of all kinds of products applying biological engineering technology, such as the semi-finished preparation of antibodies, vaccines, blood products, recombinant proteins and so on, and it can also be used for the production of culture medium, purification buffer and other auxiliary liquid preparation.
Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
 
4.CIP station system: It is used to assist in the on-line cleaning of tanks and pipelines of various preparation and bioreactor systems, and can be controlled separately or integrated with other systems.
Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes



Features

1.Modular design, cost-saving and worry-free. The pre-tested modular equipment provides significant savings on installation, faster delivery, and a high level of flexibility and convenience.

Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes

2.Fully automatic running system, intelligent and efficient. The one-button automatic control system of CIP and SIP can automatically detect the end of cleaning and sterilization, with recipe management, electronic signature, electronic records, audit tracking and other computer functions, realizing production automation.

Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes

3.Controllable production with key process parameters and visualized monitoring of the production process. When the equipment is running, it can realize controllable production of drugs with key process parameters such as temperature, dissolved oxygen, PH, etc., and automatically detect them and give an alarm when there are special circumstances outside of the set parameters, so as to avoid quality problems of drugs. 

Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes

4.3D simulation design and rational layout. Before manufacturing the equipment in our factory, we will carry out the same size ratio 3D design to rationalize the arrangement of pipelines, valves, instruments, etc. in the system to make the operation of the equipment more user-friendly. 

Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes

 
Product Parameters
 
Name Parameters
Working volume 2~15000L
Stirring speed control accuracy Speed range 0~450rpm
 ±3.0%
Temperature control accuracy Temperature range-10~150ºC
±0.2ºC
Pressure control accuracy Pressure range-0.01Mpa~0.06Mpa
±0.01MPa
Weighing control accuracy 3‰
Power supply 380V 50Hz
(Note: Other voltages require a transformer)
Sealing and protection levels IP65
 
Marya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure ProbesMarya Pharmaceutical Formulation Vessel System with Temperature and Pressure Probes
 