| Customization: | Available |
|---|---|
| Theory: | Autoclave |
| Type: | Eo(Ethylene Oxide) |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

| Rated power | 22kw |
| Inner dimension L*W*G(MM) | 4200X 1400 X 1700mm |
| Outside dimension L*W*G(MM) |
5120 X 2020 X 2320mm |
| Work pressure | 0KPa‐-60KPa |
| Working humidity | 20‰-90‰ |
| Operating temperature | 45ºC-60ºC |
| Sterilization time | 1‐99h |
| Chamber material | 304 Stainless steel/304 Stainless steel |
| Outside material | 304 Stainless steel/304 Stainless steel |
| Eliminate residue times | 0-50 times could adjust |
Sterilizer combination materials and functions |
The sterilization room adopts 304/316 imported stainless steel three-layer temperature control protection |
| Double protective door | |
| Outside 1.2mm high quality steel plate | |
| Automatic computer control of the sterilization process | |
| Leak detection function | |
| Water temperature control system throughout the whole machine | |
| Humidification system to increase sterilization effect | |
| The analysis system of ethylene oxide and water vapor after sterilization ensures the safety of operators |
|
| Use a single bottle of pure ethylene oxide for filling | |
| Sterilization purpose | Sterilize items that are not resistant to temperature, heat and humidity |
| Sterilization method | 100% Ethylene oxide gas |
| Action valve | Pneumatic valve |
| Chamber material | Stainless steel equipment and high-quality aluminum alloy |
| way to heat up | Electric heating film uniform heating |
| Printing system | During the sterilization process, a micro printer is used to print and save the entire sterilization process |
Performance description |
Negative pressure working system |
| Dual pressure control system | |
| Power-off memory function | |
| Accurate control of humidification water consumption, built-in humidity sensor | |
| Forced ventilation | |
Safety measures |
Safety automatic detection function |
| Dual temperature protection function | |
| Door safety interlocking device | |
way to control |
PLC automatic control liquid crystal display working status and operation |
| Ventilation time 3.9-99h | |
| With automatic fault detection, alarm and fault system | |
| Troubleshooting | With automatic fault detection, fault code content display alarm, Fault sound alarm and fault printing system |
| power supply | 380V 60HZ |